Application

Stack gas cleaning downstream from a coal-burning boiler for heating of greenhouse. Pulse-cleaned filter cassette from Flakt (72 oval bags as a compact cassette, 6 cassettes).

Optimization Potential

Manual cleaning required once yearly because of clogging spark damage to conventional filter bags. This led to replacement of otherwise functional filter cassettes.

Solution

Install six GORE membrane/Teflon® B fiberglass fabric (16.8 oz) filters which will prevent clogging and consequent manual cleaning. At the same time, spark damage is eliminated because the amount of fly ash on the surface is minimal and cannot sustain damage from sparks.

Results

No manual cleaning has been necessary to maintain a controlled and low pressure drop and maximum gas flow. Despite hours of poor combustion, the GORE membrane filter bags have reconditioned themselves, and the pressure drop and flow values have returned to normal.

FOR INDUSTRIAL USE ONLY

Not for use in food, drug, cosmetic or medical device manufacturing, processing, or packaging operations.