Thickness 3 mm (1/8") 6 mm (1/4")
m 2.5 2.5
y 2,750 psi 3,330 psi


This testing was conducted using 30 mm wide tape formed into a circle of 230 mm diameter.

m & y are gasket constants used for flange design as specified in the ASME Boiler and Pressure Vessel Research Code Division 1 Section VIII Appendix 2. Leak Rates versus Y stresses and m factor for Gaskets is currently being proposed as a new test method in the ASTM F03 Working Group.

Gasket Constant Definitions

m, maintenance factor, is a factor that describes the amount of additional preload required to maintain the compressive load on a gasket after internal pressure is applied to a joint. 

y, seating stress, is the minimum compressive stress (psi) required to achieve an initial seal.

Top