Technical Information
Typical
Properties
|
Installation |
|
| •
AD code of practice B7 |
|
k0 * kD = 24,5 * bD
|
|
k1 = 2,5 * bD
|
• DIN 28090 Minimum stress-to-seal
Parameter*
|
DIN (40
bar, 0,01 mg(m+s)) |
24,5 MPa |
DIN (6
bar, 0,01 mg (m * s)) |
20 MPa |
DIN  |
5 MPa |
* other parameters available on request
Maximum stress-to-seal
DIN = 150
MPa
• ASTM and PRVC parameters (design codes) are available
on request
|
To aid installation, GORE™ Series 600 Gasket Tape comes with a self-adhesive strip. The flange faces must be
carefully cleaned to ensure that the uncompressed tape does not
come into contact with contaminants such as oil or grease. As the
drawing shows, one end should start with a skived cut.
The gasket tape should be laid in the middle of the sealing width
and should start in front of a bolt hole. When the tape has been
placed around the entire circumference, lay the end over the skived
end and cut off any excess material leaving a total thickness of
approximately 120% of the original gasket height.
|
|

| Thick (mm) |
3
|
6
|
9
|
| lS (mm) |
15-25
|
25-30
|
30-40
|
|
|

|
|
Torquing
The torque values recommended by the manufacturer of the glass-lined
equipment should be observed at all times. We recommend retorquing
once after the first temperature cycle. Retorquing should be carried
out at room temperature only! We would advise you to look at our
separate installation instructions.
|
|
Availability
|
Thick(mm)
|
3
|
6
|
9
|
| Width (mm) |
|
40
|
x
|
x
|
x
|
|
55
|
x
|
x
|
x
|
|
65
|
x
|
x
|
x
|
| |
available on spools
of 2,5 or 5m |
| |
available on spools of 5, 10 or 15m
|
|
|
Size Selection
The gasket width selected should be such that after installation
the inside of the gasket tape ends roughly in line with the inside
of the equipment. Along the outside diameter of the flange the tape
should protrude at least 3mm.
For equipment measuring up to 800mm in diameter, we recommend 6mm
thick GORE™ Series 600 Gasket Tape and for larger equipment
9mm. If any irregulairties are >1mm, the 9mm thick tape must
always be used and then shimmed. In the case of irregularities over
1mm, every additional millimetre of irregularity needs to be compensated
using 3mm thick tape.
|

|
More Information
Please, visit our multilingual download page for Data Sheets, Technical PDFs, Installation Instructions etc.

|