GORE™ Series 300
Gasket Tape
Technical Information
| Typical
Properties |
Installation |
|
| •
AD code of practice B7 |
|
k0 * kD = 24,5 * bD
|
|
k1 = 2,5 * bD
|
• DIN 28090 Minimum stress-to-seal
Parameter*
|
DIN (40
bar, 0,01 mg (m s)) |
24,5 MPa |
| DIN (6 bar, 0,01 mg
(m * s)) |
20 MPa |
DIN  |
5 MPa |
*other parameters available on request
Maximum stress-to-seal
DIN s óvo = 150 MPa
Compression set
=51% (30
MPa; 20 °C)
=13% (30 MPa;
180 °C; 6h)
• ASTM and PRVC parameters (design codes) are available on
request |
To aid installation, GORE™ Series 300 Gasket
Tape comes with a self-adhesive strip. The flange faces must be
carefully cleaned to ensure that the uncompressed tape does not
come into contact with contaminants such as oil or grease. As the
drawing shows, one end should start with a skived cut. The gasket
tape should be laid in the middle of the sealing width and should
start in front of a bolt hole. When the tape has been placed around
the entire circumference, lay the end over the skived end and cut
off any excess material leaving a total thickness of approximately
120% of the original gasket height.
|
|

| Thick (mm) |
2 |
3 |
6 |
| lS (mm) |
10-20 |
15-25 |
25-35 |
|
|

|
|
In general GORE™ Series 300 Gasket Tape
should be installed as most common sealing materials. Installation
should follow standard guidelines such as those issued by the ESA
(European Sealing Association).
Download
the installation Instruction.
|
|
Availability
|
Thick (mm)
|
2
|
3
|
6
|
| Width (mm) |
|
10
|
x
|
x
|
x
|
|
15
|
x
|
x
|
x
|
|
20
|
x
|
x
|
x
|
|
25
|
x
|
x
|
x
|
|
30
|
|
x
|
x
|
|
available on spools of 5, 10 or 20 m
|
|
available on spools of 10 or 20 m
|
|
|
Size selection
The gasket width selected should cover between 30% and 50% of the
flange face. With tongue and groove flanges, the entire width of
the groove should be covered by the gasket. For steel applications,
3mm GORE™ Series 300 Gasket Tape is usually recommended.
For irregularities more than 1mm, 6mm thick tape should be used.
2mm thick tape is only used when the flanges are in perfect condition
or the equipment is new.
|

|
More
Information
Please, visit our multilingual download page for Data Sheets, Technical PDFs, Installation Instructions etc.

|