W.L. Gore & Associates · Sealant Technologies UK


GORE™ Series 300 Gasket Tape

Technical Information

Typical Properties Installation


• AD code of practice B7
k0 * kD = 24,5 * bD
k1 = 2,5 * bD

• DIN 28090 Minimum stress-to-seal

Parameter*
DIN (40 bar, 0,01 mg (m s)) 24,5 MPa
DIN (6 bar, 0,01 mg (m * s)) 20 MPa
DIN 5 MPa
*other parameters available on request

Maximum stress-to-seal

DIN s óvo = 150 MPa

Compression set
=51% (30 MPa; 20 °C)
=13% (30 MPa; 180 °C; 6h)

• ASTM and PRVC parameters (design codes) are available on request

To aid installation, GORE™ Series 300 Gasket Tape comes with a self-adhesive strip. The flange faces must be carefully cleaned to ensure that the uncompressed tape does not come into contact with contaminants such as oil or grease. As the drawing shows, one end should start with a skived cut. The gasket tape should be laid in the middle of the sealing width and should start in front of a bolt hole. When the tape has been placed around the entire circumference, lay the end over the skived end and cut off any excess material leaving a total thickness of approximately 120% of the original gasket height.

Installation GORE™ Series 300 Gasket Tape

Thick (mm) 2 3 6
lS (mm) 10-20 15-25 25-35


Installation GORE-TEX® S 300 Gasket Tape

In general GORE™ Series 300 Gasket Tape should be installed as most common sealing materials. Installation should follow standard guidelines such as those issued by the ESA (European Sealing Association).

Download the installation Instruction.

Availability

Thick (mm)
2
3
6
Width (mm)
10
x
x
x
15
x
x
x
20
x
x
x
25
x
x
x
30
x
x
available on spools of 5, 10 or 20 m
available on spools of 10 or 20 m

Size selection
The gasket width selected should cover between 30% and 50% of the flange face. With tongue and groove flanges, the entire width of the groove should be covered by the gasket. For steel applications, 3mm GORE™ Series 300 Gasket Tape is usually recommended. For irregularities more than 1mm, 6mm thick tape should be used. 2mm thick tape is only used when the flanges are in perfect condition or the equipment is new.