Case Histories
|
(1) Catalytic converter
|
| Equipment: |
Catalytic
converter |
| Operating temperature:
|
80 °C |
| Operating
pressure: |
3
bar |
|
Medium:
|
Exhaust
gas |
| Flange: |
Nominal width 400mm |
| Sealing surface: |
400mm
x 460mm x 20mm wide |
| Bolts: |
16 x M24 |
| Comments: |
Application
5 years old. GORE™ Joint Sealant
DF14
has been used since the equipment first went into service. The sealant
is only replaced during scheduled
maintenance every 6 months.
|
|
|
|
(2) Computer scanner
|
| Equipment: |
Computer scanner |
| Operating temperature:
|
Ambient |
| Operating pressure:
|
25 bar |
| Medium: |
Xenon |
| Flange:
|
Tongue and groove,
aluminium, very low bolt load, diameter 250mm |
| Sealant: |
GORE™
Joint Sealant DF03 |
|
(3) Heat exchanger
|
| Equipment: |
Graphite
block heat exchanger |
| Operating temperature:
|
120 °C |
| Operating pressure:
|
20 bar |
| Medium: |
Various |
| Flange: |
700mm diameter |
| Sealant: |
GORE™ Joint
Sealant DF10 |
|
(4) Wind tunnel
|
| Equipment: |
Wind tunnel |
| Operating temperature: |
-180 °C to +20??C |
| Operating pressure: |
4,5 bar |
| Medium: |
Liquid Nitrogen |
| Flange: |
Steel housing cover |
| Sealant: |
GORE™
Joint Sealant DF10 |

|
More
Information
Please, visit our multilingual download page for Data Sheets, Technical PDFs, Installation Instructions etc.

|