GORE® Turbine Filters – Conical Filter Pairs - E12
More Power
GORE® Turbine Filters optimize power output by eliminating performance reducing deposits in your compressor section. Their outstanding E12 filtration efficiency keeps out at least 99.5% of contaminants at the most penetrating particle sizes (~0.1 μm). This stops power losses while reducing your fuel consumption and associated CO2 and NOx emissions. Machine availability and reliability are also significantly increased because there is no need to stop the turbine for off-line compressor washing.
Less Wear
GORE® Turbine Filters significantly reduce your maintenance costs while increasing compressor and turbine lifetimes. Unlike current air intake filters, they capture at least 99.5% of atmospheric particles, and have a unique patented filter media that is waterproof and provides reliable protection from corrosive salts. This reduces unexpected failures and major outages by preventing both fine and corrosive particulates from reaching the engine. GORE® Turbine Filters also directly replace your existing filters with no modifications required to filter housing.
Features
- >99.5% Filtration Efficiency at MPPS (E12)
- Very Low Initial Pressure Drop
- Watertight and Salt Repellent
- High Burst Pressure
Benefits
- Higher Power Output
- Increased Turbine Availability
- No Filter House Modifications Required
- Less Fuel Costs
- Less Maintenance Costs
Effect of Compressor Fouling on Power Output
Field Results: Elimination of Off-Line Washes
Construction Materials
| Filter Media | Fully Synthetic Composite with ePTFE Membrane | |
|---|---|---|
| Endcaps | Galvanized or Stainless Steel | |
| In-/Outside Liner | Galvanized or Stainless Steel | |
| Potting | Polyurethane | |
| Gasket | EPDM Rubber | |
Application Performance
| Efficiency | E12 according to EN 1822 Min. 99.5% @ MPPS |
|
|---|---|---|
| Wet Burst Pressure | 7500 Pa (30" wc) | |
| Initial Pressure Drop | 210 Pa @ 4800 m³/h (.84" wc @ 2825 cfm) |
|
| Temperature Range | -40°C to +65°C (-40°F to +149°F) |
|
| Humidity Range | 0 to 100% relative humidity | |
| Flame Retardance | E d2 according to EN 13501 | |
Dimensions
| Large Cone | Small Cone | |
| Large End OD | 570 mm (22 .44") | 445 mm (17.5") |
|---|---|---|
| Small End OD | 445 mm (17.5") | 323 mm (12.75") |
| Length | 710 mm (28") | 710 mm (28") |
| Other sizes available upon request. Direct replacement of most conventional filters with no modifications required to filter housing. |
||
Operational Mode - Static
FOR INDUSTRIAL USE ONLY.
Not for use in food, drug, cosmetic or medical device manufacturing, processing, or packaging operations