Hosakawa/MikroPul pulse jet collector (31 bags). Gas flow 1,100 acfm (ambient), air-to-cloth ratio 4.84/1 gross, lift velocity 2.59 fps, particle size 20 to 30 microns. New system.
1. Need to minimize potential for highly visible emissions; 2. Need to maximize life on effluent gas stream secondary filter and maximize product yield in collector; 3. Need to minimize potential for static build-up in system.
Installed GORE® membrane/anti-static polyester felt filter bags (14 oz).
No visible emissions. Excellent and consistent product yield. Secondary filter blinding significantly reduced. No bag failures since installation (six months).
Not for use in food, drug, cosmetic or medical device manufacturing, processing, or packaging operations