Examination or Test
|
Applicable Standards
|
Status
|
|
Design and construction
|
MIL-T-81490 paragraph 4.7.1
|
Compliant
|
|
Marking
|
MIL-T-81490 paragraph 4.7.1
|
Compliant
|
|
Workmanship
|
MIL-T-81490 paragraph 4.7.2
|
Compliant
|
|
RF insertion loss
|
MIL-T-81490 paragraph 4.7.3
|
Compliant
|
|
Voltage standing wave ratio
|
MIL-T-81490 paragraph 4.7.4
|
Compliant
|
|
Impedance
|
MIL-T-81490 paragraph 4.7.5
|
Compliant
|
|
Vapor leakage
|
MIL-STD-202F, notice 9, method 112E paragraph 5, condition C, procedure IV
|
Compliant
|
|
Velocity of propagation
|
MIL-T-81490 paragraph 4.7.7
|
Compliant
|
|
RF leakage
|
MIL-STD-1344, method 30008
|
Compliant
|
|
Thermal shock
|
MIL-STD-810D, method 503.2
|
Compliant
|
|
Power handling capability
|
MIL-T-81490 paragraph 4.7.13
|
Compliant
|
|
Flexure
|
MIL-T-81490 paragraph 4.7.15
|
Compliant
|
|
Torque
|
MIL-T-81490 paragraph 4.7.16, torque requirement of 50 in/lbs replaced by ±90° angular displacement
|
Compliant
|
|
Tensile load
|
MIL-T-81490 paragraph 4.7.17
|
Compliant
|
|
Concentrated load
|
MIL-T-81490 paragraph 4.7.18, 100 ±2 lbs force
|
Compliant. Achieved ≥ 400lbs
|
|
Abrasion
|
MIL-T-81490 paragraph 4.7.19
|
Compliant
|
|
Sand and dust
|
MIL-STD-810D, method 510.2, procedure I
|
Compliant
|
|
High potential withstanding voltage
|
MIL-STD-202, method 301
|
Compliant
|
|
Explosive atmosphere
|
MIL-STD-810, method 511
|
Compliant
|
|
Temperature / humidity / altitude / vibration
|
MIL-STD-810D, method 520.0, procedure III with vibration as per MIL-STD-810D, method 514.3, procedure I
|
Compliant
|
|
Humidity
|
MIL-STD-810, method 507
|
Compliant
|
|
Vibration
|
MIL-STD-810D, method 514.3, procedure I
|
Compliant
|
|
Gunfire vibration
|
MIL-STD-810D, method 519.3 procedure I, test spectra fig. 519.3-1
|
Compliant
|
|
Salt fog
|
MIL-STD-810D, method 509, exposure ≥ 96 hours
|
Compliant. Achieved ≥ 500 hours
|
|
Examination or Test
|
Applicable Standards
|
Status
|
|
Chemical resistance
|
BS3G100, part 2, section 3, subsection 3.12, for class A
Fluids tested:
1. Avtag F.40 ( JP-4)
2. Avtur F.34 (JP-8)
3. Hydraulic fluid OM 15
4. Cabin seal compound
5. Engine & gearbox oil 156.000
6. De-icing fluid S737
7. De-icing fluid (windscreen)
8. De-icing fluid (aircraft) S1746
9. De-icing fluid (runway)
10. Sea water
11. Heat transfer liquid
12. Engine corrosion inhibiting fluid OM 13
13. Aircraft washing agent(s)
14. Corrosion preventive compound
15. Aircraft cleaning compound
|
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
|
|
Icing freezing rain
|
MIL-STD-810D, method 521.0
|
Compliant
|
|
Fungus resistance
|
MIL-STD-810D, method 508.3
|
Compliant
|
|
Acoustic noise
|
MIL-STD-810D, method 515.3, procedure II
|
Compliant
|
|
Mechanical shock
|
MIL-STD-810D, method 516.3, procedures I, V & VI
|
Compliant
|
|
Drip
|
MIL-STD-810D, method 506.2, procedure II
|
Compliant
|
|
Rain
|
MIL-STD-810D, method 506.2 procedure I
|
Compliant
|
|
Fire resistance
|
MIL-STD-202F, method 111 and MIL-C-17F, paragraphs 3.7.22 and 4.8.23
|
Compliant
|
|
Corona extinction voltage
|
MIL-C-17, paragraphs 3.7.5 and 4.8.6
|
Compliant
|
|
Endurance
|
MIL-C-39012, paragraphs 3.15 and 4.6.12
|
Compliant
|
|
Acceleration
|
MIL-STD-810D, method 513.3 procedures I and II
|
Compliant
|
|
Flammability
|
FAR25.853 (a) appendix F part 1 (b)(7)
|
Compliant
|
|
Toxicity
|
FAR25.853 (a) appendix F part 1 (b)(7)
|
Compliant
|
|
Smoke
|
FAR25.853 (a) appendix F part 1 (b)(7)
|
Compliant
|