Low Loss Power Transmission Cables
 Cables used in power transmission systems are subject to electrical, thermal, and system-related influences.
Gore cable meets the requirements of all of these factors.
Benefits
-
Lowest loss related to cable diameter
-
High power handling capability
-
Best phase stability
-
High flexibility and flex life
Technical Data
|
Cable type
|
GSC-14-786-00
|
GSC-14-786-01
|
|
Diameter
|
[mm nom]
[inch nom]
|
23.0
.906
|
20.0
.787
|
|
Impedance
|
Ω
|
50
|
50
|
|
Operating frequency
|
5,000 MHz max
|
6,000 MHz max
|
|
Power handling
capability at 100 MHz
|
10 kW cw max
|
5 kW cw max
|
|
Bending radius
|
[mm min]
[inch min]
|
200
7.88
|
150
5.90
|
|
Weight
|
[g/m nom]
[pound/ft nom]
|
550
.076
|
470
.065
|
|
Operating
temperature range
|
[ °C]
[ °F]
|
-40 to +100
-40 to +212
|
-40 to +100
-40 to +212
|
Power handling capability of cable GSC-14-786-00
Assembled with flange EIA 1 5/8' or connector 13-30
|
Frequency (MHz)
|
30
|
100
|
200
|
400
|
600
|
800
|
1,000
|
2,000
|
4,000
|
|
Power handling capability
at +40°C ambient temperature
(kW cw max)
|
15
|
10
|
6.5
|
4.5
|
3.5
|
3.0
|
2.5
|
2.0
|
1.5
|
Power handling capability of cable GSC-14-786-01
Assembled with flange EIA 7/8' or connector 7-16
|
Frequency (MHz)
|
30
|
100
|
200
|
400
|
600
|
800
|
1,000
|
2,000
|
4,000
|
|
Power handling capability
at +40°C ambient temperature
(kW cw max)
|
8
|
5
|
4.2
|
3.3
|
2.9
|
2.4
|
2.0
|
1.6
|
1.2
|
Attenuation of cable GSC-14-786-01 (incl. connectors)
|
Frequency (MHz)
|
30
|
100
|
200
|
400
|
800
|
1,000
|
2,000
|
4,000
|
|
Attenuation (dB/m nom)
|
0.02
|
0.03
|
0.04
|
0.05
|
0.07
|
0.09
|
0.12
|
0.17
|
Return loss of cable GSC-14-786-00 and -01 (incl. connectors)
|
Frequency (MHz)
|
30
|
100
|
200
|
400
|
800
|
1,000
|
2,000
|
4,000
|
|
Return loss (dB/m nom)
|
30
|
30
|
30
|
27
|
27
|
25
|
25
|
22
|
|
VSWR
|
1.06 : 1
|
1.09 : 1
|
1.12 : 1
|
1.18 : 1
|
|